Electrolyzer Of Acidic Oxidation Potential Water

Electrolyzer Of Acidic Oxidation Potential Water

Place of Origin: Shaanxi,China
Payment terms: TT/ L/C /West Union
MOQ: 1 set of(sample is available)
Diaphragm:Ionic membrane
Accessories: Titanium bolt、O-ring etc.
Package details: Standard exporting wooden cases or as you required

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction

Electrolyzer of Acidic Oxidation Potential Water – Model DNE‑120

What Is Acidic Oxidation Potential Water?

Acidic oxidation potential water (also known as electrolyzed oxidizing water) is a powerful yet safe disinfectant produced by electrolysis of a dilute salt solution. It has been widely used in healthcare, food processing, agriculture, and water treatment due to its strong bactericidal effect and environmentally friendly nature.

The core component that produces this water is the electrolyzer. Di Noer presents the Model DNE‑120 Electrolyzer of Acidic Oxidation Potential Water – a compact, efficient, and reliable solution for on‑site generation of acidic electrolyzed water.

Product Overview

Product Item Description
Product name Electrolyzer of acidic oxidation potential water
Model DNE‑120
Dimensions 135 × 44 × 70 mm
pH value 2.0 – 3.0
Water treatment capacity ≤ 150 L/h
Acid yield 45 L/h
Current < 15 A
Voltage < 24 V
Effective chlorine content 50 – 70 mg/L
Redox potential (ORP) ≥ +1100 mV

Key Features of DNE‑120 Electrolyzer

1. Strong Disinfection Performance

With an ORP of ≥ +1100 mV and effective chlorine content of 50–70 mg/L, the acidic oxidation potential water produced by this electrolyzer demonstrates strong bactericidal activity against a wide range of pathogens, including bacteria, viruses, and fungi.

2. Low pH Range

The output water has a pH of 2.0–3.0, which is characteristic of acidic oxidation potential water. This low pH environment, combined with high ORP and available chlorine, creates the disinfection mechanism.

3. Compact and Practical Design

Measuring only 135 × 44 × 70 mm, the DNE‑120 is small enough to integrate into various equipment or systems. Despite its size, it delivers a water treatment capacity of up to 150 L per hour and an acid yield of 45 L/h.

4. Energy Efficient

Operating at <15 A current and <24 V voltage, this electrolyzer balances performance with reasonable energy consumption.

Technical Parameters at a Glance

Parameter Value
Model DNE‑120
Size 135×44×70 mm
pH 2.0–3.0
Treatment capacity ≤150 L/h
Acid yield 45 L/h
Current <15 A
Voltage <24 V
Effective chlorine 50–70 mg/L
ORP ≥ +1100 mV

Applications of Acidic Oxidation Potential Water Electrolyzer

The DNE‑120 electrolyzer is suitable for integration into:

Disinfection equipment for hospitals and clinics

Food processing sanitation systems

Agricultural sterilization units

Water treatment stations

Industrial cleaning systems

Household or commercial electrolyzed water generators

 

 

0c14d1c29db4f734d5c884880cb8212

 

58d66acda1e8a4be92d976592395271

Why Choose Di Noer Electrolyzer DNE‑120?

Stable output – Consistent pH, ORP, and chlorine content

Compact footprint – Easy to install in new or existing systems

Reliable performance – Designed for continuous operation

Proven electrolysis technology – Backed by Di Noer's experience in electrochemical equipment

FAQ – Electrolyzer of Acidic Oxidation Potential Water

1. What is the difference between acidic oxidation potential water and regular bleach?

Acidic oxidation potential water is much safer for humans and the environment. It degrades quickly back into ordinary water, leaving no harmful residues. Bleach (sodium hypochlorite) leaves chemical residues and requires rinsing.

2. Do I need any special maintenance for the DNE‑120 electrolyzer?

Routine maintenance is minimal. However, periodic inspection of the electrode surfaces and proper rinsing are recommended to prevent scaling, especially if feed water has high hardness.

3. What feed water quality is required?

For optimal performance and longer electrolyzer life, we recommend using softened water or water with low hardness. High hardness may cause scaling on the electrode surfaces over time.

4. Can the acid yield be adjusted?

The acid yield of 45 L/h is the rated output. In some designs, you can adjust flow rate and current within certain limits, but we recommend consulting Di Noer before making changes to avoid affecting water quality parameters.

5. What is the expected service life of the DNE‑120 electrolyzer?

Service life depends on operating conditions, including water quality, duty cycle, and maintenance. Under normal conditions with proper feed water, the electrolyzer can operate reliably for several years.

6. Is the electrolyzer safe to operate?

Yes. The DNE‑120 operates at low voltage (<24 V) and is designed with safety in mind. However, standard electrical safety practices should always be followed during installation and use.

7. Can I customize the size or output parameters?

Customization is possible. Please contact Di Noer with your specific requirements, and our engineering team will evaluate the feasibility.

Contact Di Noer

If you are looking for a reliable electrolyzer of acidic oxidation potential water – whether for a new product development or to replace an existing component – please reach out to Di Noer. We provide standard models like the DNE‑120 as well as custom solutions.

Di Noer – Your partner in electrolysis technology for water treatment and disinfection.

 

Hot Tags: electrolyzer of acidic oxidation potential water, suppliers, manufacturers, factory, customized, buy, price, quality, pricelist, in stock, for sale, titanium electrolyzer for agricultural electrolyte electrolysis, titanium electrolyzer for biosynthesis electrolyte electrolysis, titanium electrolyzer for stabilizer electrolyte electrolysis, titanium electrolyzer for hazardous waste treatment electrolyte electrolysis, titanium electrolyzer for enzyme electrolyte electrolysis, titanium electrolyzer for waste water treatment electrolyte electrolysis

You Might Also Like

(0/10)

clearall