Di Noer Completes Post-Coating Edge Inspection On Expanded-Mesh Anodes; Several Pieces Returned For Active-Face Chipping

Nov 16, 2026

Report​ A batch of Grade 2 expanded-mesh MMO titanium anodes has undergone piece-by-piece edge inspection after cutting, deburring and thermal-decomposition coating, the coating workshop said. Several pieces showed discontinuous coating along the active-face edge and were returned under batch records, without entering packing.
Mesh anodes are not a continuous surface: the openings, strands and cut ends behave differently from plate, and edge and back-face coverage needs its own check, staff said. After coating, all four edges were examined under standard lighting, with a stereo microscope used where needed. Exposed titanium, lifting and flaking were logged by position; suspect areas were marked and photographed.
The returned pieces were grouped along the same cut edge. Comparing against the first-piece record for the batch, inspectors initially put it down to uneven chamfering and residual burr. Under the shop's standing rule, minor damage outside the active area can be patched with the supplier's compound, while damage on the active face changes local current distribution and is normally rejected - which is how these were handled, without repair or mixing into the lot.
The rest of the batch passed, moved on to packing with soft interleaving, piece numbers matched to the batch number, and inspection records and images filed under that batch. At the time of filing, the returned pieces were tagged and quarantined; the shift's furnace schedule was unchanged.